Support Centre for Installers

All AC module installations must be Internet connected for the monitoring to receive the 25-year microinverter warranty. This Internet connection reports data to the Enphase monitoring platform, Enlighten on a per microinverter/module basis. The performance of each microinverter and module is visible to the installer via Enlighten and alerts are provided for any faulty equipment, such as an under-performing PV module or a faulty microinverter.
In single-phase, 10 microinverters can be connected. In a three-phase installation, up to 30 microinverters can be connected on a single 20A three phase circuit breaker. Larger systems can be constructed with multiple AC branch circuits.
No, export limiting functionality is not yet compliant with RD 244/2019. Most installations with Enphase microinverters are residential scale (below 15kW) and are easily accepted without this compliance.
Each microinverter is a single phase device. Three-phase installations are constructed with single phase microinverters distributed across the phases. The inverter will monitor power consumption at each phase using the CTs connected to the Envoy-S communications gateway, limiting grid export to the defined level, either on a per phase or aggregate basis as required.In three-phase installations, can you divide surpluses by phases?