Some customers have achieved some clever customised DIY solutions for re-directing surplus power using Enphase APIs, however, Enphase does not currently offer products that re-direct surplus power.
If the microinverter (or the associated PV module) should fail, only that PV module is offline. The remainder of the system continues to operate as normal – a key benefit of AC modules.
All AC module installations must be Internet connected for the monitoring to receive the 25-year microinverter warranty. This Internet connection reports data to the Enphase monitoring platform, Enlighten on a per microinverter/module basis. The performance of each microinverter and module is visible to the installer via Enlighten and alerts are provided for any faulty equipment, such as an under-performing PV module or a faulty microinverter.
Costs vary from project to project. Performance panels generally have a price point that is competitive with Conventional Panels.
Your system will automatically shut down. Safety requirements prohibit the system from producing electricity during a power outage or blackout, because there is a chance that the system could feed electricity into the electric grid while utility workers are accessing the grid. The system will restart automatically when power is restored.
The Enphase three-phase Q Cable allows balanced and automated power management of each phase. Alternatively, when using three single-phase cables, care must be taken to balance the phases by installing a similar number of panels on each phase.
The Envoy-S communications gateway can also provide phase imbalance monitoring to ensure authorised limits are not exceeded. The Envoy is able to manage PV power production at the microinverter level to maintain balance within set limits.