Support Centre for Installers

Some customers have achieved some clever customised DIY solutions for re-directing surplus power using Enphase APIs, however, Enphase does not currently offer products that re-direct surplus power.
If the microinverter (or the associated PV module) should fail, only that PV module is offline. The remainder of the system continues to operate as normal – a key benefit of AC modules.
Your system will automatically shut down. Safety requirements prohibit the system from producing electricity during a power outage or blackout, because there is a chance that the system could feed electricity into the electric grid while utility workers are accessing the grid. The system will restart automatically when power is restored.
The Enphase three-phase Q Cable allows balanced and automated power management of each phase. Alternatively, when using three single-phase cables, care must be taken to balance the phases by installing a similar number of panels on each phase.
The Envoy-S communications gateway can also provide phase imbalance monitoring to ensure authorised limits are not exceeded. The Envoy is able to manage PV power production at the microinverter level to maintain balance within set limits.
If an issue is detected via the Enlighten monitoring platform, please contact Enphase Customer Support. If the issue is related to the microinverter, Enphase will provide any service required under their warranty coverage. If Enphase determines the issue is related to the panel, the service will be transferred and supported by Maxeon Solar Technologies under the appropriate SunPower panel line warranty.